Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Ultramid® Advanced N3U41G6 - PA9T-GF30 FR(40) - BASF

Material Data Center offers the following functions for Ultramid® Advanced N3U41G6:
unit conversion, PDF datasheet print, comparison with other plastics, snap fit calculation, beam deflection calculation, parameters for material models, CAE Interfaces

Check here, which other Ultramid A datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Informação do produto
Polyphthalamide, light colorable, with a high melting point, halogen-free flame-retardant, very low water absorption, good mechanical and dielectrical properties at elevated temperatures as well as excellent chemical resistance, soldering bath resistant. Colors available (e.g. Orange RAL 2003).

Markets & applications
Automotive: Automotive electrics & electronics (E&E), sensors, fuel cell, e-mobility
E&E: Connectors, SMT (surface mount technology) applications, energy distribution
Consumer goods: Home appliances, consumer electronics, cell phone parts
Características de processamento/físicasSeco / CondUnidadeMétodo de ensaio
ISO Dados
Índice de fluidez volumétrico, MVR 30 / * cm³/10min ISO 1133
Temperatura 325 / * °C -
Carga 5 / * kg -
Contração após a moldagem, paralelo 0.3 / * % ISO 294-4, 2577
Contração após a moldagem, perpendicular 1.0 / * % ISO 294-4, 2577
Propriedades mecânicasSeco / CondUnidadeMétodo de ensaio
ISO Dados
Módulo de tração 10500 / 10500 MPa ISO 527
Tensão na ruptura 140 / 130 MPa ISO 527
Deformação na ruptura 2.2 / 2.2 % ISO 527
Resistência ao impacto Charpy , +23°C 60 / 50 kJ/m² ISO 179/1eU
Resistência ao impacto Charpy, -30°C 60 / - kJ/m² ISO 179/1eU
Res. impacto Charpy c/entalhe, +23°C 6.5 / 6.5 kJ/m² ISO 179/1eA
Propriedades térmicasSeco / CondUnidadeMétodo de ensaio
ISO Dados
Temperatura de fusão, 10°C/min 300 / * °C ISO 11357-1/-3
Temperatura de deflexão térmica, 1.80 MPa 265 / * °C ISO 75-1/-2
Coef. de expansão térmica linear, paralelo 19 / * E-6/K ISO 11359-1/-2
Coef. de expansão térmica linear, perpend. 53 / * E-6/K ISO 11359-1/-2
Flamabilidade a 1.5mm esp. nom. V-0 / * class IEC 60695-11-10
Espessuras do tubo de teste 1.6 / * mm -
Cartão Amarelo (yellow card) disponível sim / * - -
Flamabilidade a espessura h V-0 / * class IEC 60695-11-10
Espessuras do tubo de teste 0.2 / * mm -
Cartão Amarelo (yellow card) disponível sim / * - -
Flamabilidade 5V a espessura h 5VA / * class IEC 60695-11-20
Espessuras do tubo de teste 1.6 / * mm -
Cartão Amarelo (yellow card) disponível sim / * - -
Flamabilidade conforme índice de oxigênio 38 / * % ISO 4589-1/-2
Propriedades elétricasSeco / CondUnidadeMétodo de ensaio
ISO Dados
Constante dielétrica, 1MHz 4.1 / 3.5 - IEC 62631-2-1
Fator de dissipação dielétrica, 1MHz 110 / 160 E-4 IEC 62631-2-1
Resistividade volumétrica específica 1E13 / 1E13 Ohm*m IEC 62631-3-1
Resistividade superficial específica * / 1E15 Ohm IEC 62631-3-2
Resistência elétrica 45 / 44 kV/mm IEC 60243-1
Índice comparativo de linha de fuga - / 600 - IEC 60112
Outras propriedadesSeco / CondUnidadeMétodo de ensaio
Absorção de água 2.1 / * % Sim. to ISO 62
Absorção de umidade 0.85 / * % Sim. to ISO 62
Densidade 1440 / - kg/m³ ISO 1183
Propriedades específicas do materialSeco / CondUnidadeMétodo de ensaio
ISO Dados
Índice de viscosidade 100 / * cm³/g ISO 307, 1157, 1628
Recomendação de processamento Moldagem por injeçãoValorUnidadeMétodo de ensaio
Pré-secagem - temperatura 120 °C -
Pré-secagem - tempo 8 h -
Umidade do processamento ≤0.05 % -
Temperatura da massa 310 - 340 °C -
Temperatura do molde 100 - 160 °C -
Diagrama
Viscosidade - taxa de cisalhamento , Ultramid® Advanced N3U41G6, PA9T-GF30 FR(40), BASF
Tensão de cisalhamento - taxa de cisalhamento , Ultramid® Advanced N3U41G6, PA9T-GF30 FR(40), BASF
Tensão - deformação , Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Tensão - deformação , Ultramid® Advanced N3U41G6 (cond.), PA9T-GF30 FR(40), BASF
Módulo secante - deformação , Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Módulo secante - deformação , Ultramid® Advanced N3U41G6 (cond.), PA9T-GF30 FR(40), BASF
Tensão - deformação (isocrônico) 23°C, Ultramid® Advanced N3U41G6 (cond.), PA9T-GF30 FR(40), BASF
Módulo de fluência - tempo 23°C, Ultramid® Advanced N3U41G6 (cond.), PA9T-GF30 FR(40), BASF
Curva de fluencia 23°C, Ultramid® Advanced N3U41G6 (cond.), PA9T-GF30 FR(40), BASF
Tensão - deformação (isocrônico) 60°C, Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Módulo de fluência - tempo 60°C, Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Curva de fluencia 60°C, Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Tensão - deformação (isocrônico) 90°C, Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Módulo de fluência - tempo 90°C, Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Curva de fluencia 90°C, Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Tensão - deformação (isocrônico) 120°C, Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Módulo de fluência - tempo 120°C, Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Curva de fluencia 120°C, Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Tensão - deformação (isocrônico) 150°C, Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Módulo de fluência - tempo 150°C, Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Curva de fluencia 150°C, Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Módulo de tração - temperatura , Ultramid® Advanced N3U41G6 (dry), PA9T-GF30 FR(40), BASF
Módulo de tração - temperatura , Ultramid® Advanced N3U41G6 (cond.), PA9T-GF30 FR(40), BASF
Características
Processamento
Moldagem por injeção
Características especiais
Retardante de chama, Sem halogéneo
Características
Resistência de derreta, Estabilidade térmica
Resistência Química
Resistência química geral
Aplicaciones
Automóvel, Elétrica e Eletrônica
Disponibilidade regional
Outras informações
Moldagem por injeção
PREPROCESSING
Pre/Post-processing, max. allowed water content: .05 %
Pre/Post-processing, Pre-drying, Temperature: 120 °C
Pre/Post-processing, Pre-drying, Time: 8 h

PROCESSING
injection molding, Melt temperature, range: 310 - 340 °C
injection molding, Melt temperature, recommended: 330 °C
injection molding, Mold temperature, range: 100 - 160 °C
injection molding, Mold temperature, recommended: 140 °C
injection molding, Dwell time, thermoplastics: 5 min
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.